This is a working overview of anti-doping, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-08-01 and is reviewed periodically as new material appears.
SR9009 is a synthetic small molecule that acts on the nuclear receptors REV-ERBα and REV-ERBβ. These receptors are part of the circadian clock machinery and normally repress transcription of certain target genes. In laboratory research, SR9009 is used as a chemical tool to study how REV-ERB activity influences metabolism, inflammation, and daily biological rhythms. The compound is not an approved medicine, and its effects in humans remain largely uncharacterized. It is often described as an investigational agent rather than a therapeutic product.
REV-ERB proteins typically suppress gene expression by recruiting corepressor complexes to DNA response elements. SR9009 binds these receptors and strengthens that repressive action in cell-based assays. Studies in rodents have reported changes in lipid handling, mitochondrial function, and exercise capacity after treatment. Such findings are often cited as evidence for metabolic effects, but species differences and limited pharmacokinetic data make direct translation to humans uncertain. Researchers continue to examine which effects are robust and which depend on specific experimental conditions.
Identity and purity of SR9009 samples are usually checked with chromatographic and spectrometric methods. High-performance liquid chromatography can separate the compound from related impurities, while mass spectrometry provides molecular mass confirmation. Nuclear magnetic resonance spectroscopy may be used for structural verification in research settings. No single method proves biological activity, and certificates of analysis should be reviewed alongside raw data. Independent testing is often needed because online products vary widely.
SR9009 stability depends on temperature, moisture, light, and solvent. Solid material is generally kept cool and dry, while solutions may require protection from repeated warming and cooling. Degradation can appear as color changes, precipitate, or new chromatographic peaks. Researchers should follow supplier instructions and their own stability data. Long-term storage conditions for human use have not been established because the compound lacks approved clinical formulation.
SR9009 is supplied as a solid research chemical, often in milligram quantities. Laboratories typically weigh it in a controlled environment because fine powders can disperse. Stock solutions are commonly prepared in dimethyl sulfoxide and stored in small aliquots to reduce freeze-thaw cycles. Personal protective equipment and chemical fume hoods are standard when handling unknown or potent compounds. These practices address laboratory safety rather than human use.
| Property | Value | Notes |
|---|---|---|
| Common name | SR9009 | Also marketed informally as Stenabolic |
| Chemical class | Synthetic REV-ERB agonist | Binds REV-ERBα and REV-ERBβ |
| Molecular formula | C24H30ClN3O4S | Approximate molecular weight 492 g/mol |
| CAS Registry Number | 1379686-30-2 | Identifier for the parent compound |
| Regulatory status | Not approved for human use | Prohibited in sport by WADA |
Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.
SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.
For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.
Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.
Regulatory treatment of SR9009 varies by country and region. It is not approved as a pharmaceutical, and several jurisdictions restrict its sale for human consumption. Some authorities classify it as a research chemical, a prescription-only substance, or a prohibited performance-enhancing agent in sport. Purchasers may encounter certificates of analysis, but these documents do not guarantee identity, purity, or legality. In research settings, institutional safety reviews and controlled procurement help ensure that materials are handled under appropriate oversight. The absence of harmonized rules means that legal status can change and requires verification.
Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.
Quality control for research materials includes identity confirmation by nuclear magnetic resonance and purity assessment by high-performance liquid chromatography. Mass spectrometry provides molecular weight confirmation and can detect related impurities. Purchasers should request a certificate of analysis that lists lot-specific data. Online products advertised for human use often lack such documentation. Distinguishing legitimate research material from mislabeled or contaminated samples is a recurring challenge in independent testing, and independent laboratories may use orthogonal methods to verify identity.
Detection of SR9009 in biological samples usually relies on liquid chromatography coupled to tandem mass spectrometry. This approach separates the compound from matrix components and identifies it by mass transitions. Because SR9009 can undergo metabolism, laboratories often look for both parent drug and specific metabolites. Sample preparation may involve protein precipitation or solid-phase extraction. Method validation examines sensitivity, carryover, and interference from related substances, and reference standards are required for accurate calibration.
Storage recommendations for SR9009 reference material typically specify a freezer at -20 °C or lower, with protection from moisture and light. Repeated freeze-thaw cycles can degrade small molecules and introduce variability. Stock solutions in dimethyl sulfoxide are often aliquoted to avoid repeated handling. Stability studies may examine degradation under heat, humidity, and light exposure. The compound's thiophene and nitro groups can participate in reactions that alter analytical signals over time, so such changes affect quantitative results.
Handling recommendations for SR9009 in a laboratory setting include storing the solid at low temperature, protected from light and moisture. The compound is often dissolved in dimethyl sulfoxide or ethanol for experiments. Solutions should be prepared with appropriate personal protective equipment and disposed of according to local rules. Stability data for long-term storage are limited, so stock solutions are typically kept cold and used within defined periods. Records of preparation date and concentration support reproducibility.
SR9009 is not approved as a medicine by major regulatory agencies. It is commonly sold as a research chemical, a category that may fall outside customary drug approval and quality rules. In sports, the World Anti-Doping Agency lists SR9009 as a prohibited substance. Athletes who use it can face sanctions if it is detected in a sample. Legal status varies by country, and importation may be restricted. Enforcement practices differ across borders.
=== January 2008 === In the third week of January 2008, the SENSEX experienced huge falls along with other markets around the world. On 21 January 2008, the SENSEX saw its highest ever loss of 1,408 points at the end of the session. The SENSEX recovered to close at 17,605.40 after it tumbled to the day's low of 16,963.96, on high volatility as investors panicked following weak global cues amid fears of a recession in US. The next day, the BSE SENSEX index went into a free fall. The index hit the lower circuit breaker in barely a minute after the markets opened at 10 am. Trading was suspended for an hour. On reopening at 10.55 am IST, the market saw its biggest intra-day fall when it hit a low of 15,332, down 2,273 points. However, after reassurance from the Finance Minister of India, the market bounced back to close at 16,730 with a loss of 875 points. Over the course of two days, the BSE SENSEX in India dropped from 19,013 on Monday morning to 16,730 by Tuesday evening or a two-day fall of 13.9%. Less than a month later, on 11 February 2008, the SENSEX lost 833.98 points, when Reliance Power fell below its IPO price in its debut trade after a high-profile public offer.
Corals' many colors give it appeal for necklaces and other jewelry. Intensely red coral is prized as a gemstone. Sometimes called fire coral, it is not the same as fire coral. Red coral is very rare because of overharvesting. In general, it is inadvisable to give coral as gifts since they are in decline from stressors like climate change, pollution, and unsustainable fishing. Always considered a precious mineral, "the Chinese have long associated red coral with auspiciousness and longevity because of its color and its resemblance to deer antlers (so by association, virtue, long life, and high rank". It reached its height of popularity during the Manchu or Qing Dynasty (1644–1911) when it was almost exclusively reserved for the emperor's use either in the form of coral beads (often combined with pearls) for court jewelry or as decorative Penjing (decorative miniature mineral trees). Coral was known as shanhu in Chinese. The "early-modern 'coral network' [began in] the Mediterranean Sea [and found its way] to Qing China via the English East India Company". There were strict rules regarding its use in a code established by the Qianlong Emperor in 1759. By the middle of the 19th century, "coral fisheries" existed in the Mediterranean, the Red Sea, Persian Gulf and elsewhere. An instrument used to retrieve the coral consisted of two beams of heavy wood attached to each other at right angles. Heavy stones were added to make the apparatus sink and netting was attached beneath the device.
== Further reading == Jumhawan, U.; Putri, S. P.; Yusianto; Marwani, E.; Bamba, T.; Fukusaki, E. (2013). "Selection of Discriminant Markers for Authentication of Asian Palm Civet Coffee (Kopi Luwak): A Metabolomics Approach" (PDF). Journal of Agricultural and Food Chemistry. 61 (33): 7994–8001. doi:10.1021/jf401819s. PMID 23889358. Archived from the original (PDF) on 31 May 2019. Jumhawan, U.; Putri, S. P.; Yusianto; Bamba, T.; Fukusaki, E. (2016). "Quantification of coffee blends for authentication of Asian palm civet coffee (Kopi Luwak) via metabolomics: A proof of concept". Journal of Bioscience and Bioengineering. 122 (1): 79–84. doi:10.1016/j.jbiosc.2015.12.008. PMID 26777237. Jumhawan, U.; Putri, S. P.; Yusianto; Bamba, T.; Fukusaki, E. (2015). "Application of gas chromatography/flame ionization detector-based metabolite fingerprinting for authentication of Asian palm civet coffee (Kopi Luwak)" (PDF). Journal of Bioscience and Bioengineering. 120 (5): 555–561. doi:10.1016/j.jbiosc.2015.03.005. PMID 25912451. Archived from the original (PDF) on 31 May 2019. Sulihkanti, A.; Wahyudi, T.; Tunjung Sari, A. B. (2012). "Analysis of luwak coffee volatile by using solid phase microextraction and gas chromatography (Analisa senyawa volatil kopi luwak dengan menggunakan mikroekstrasi fase padat dan kromatolgi gas)". Pelita Perkebunan. 28 (2): 111–118. doi:10.22302/iccri.jur.pelitaperkebunan.v28i2.204. Archived from the original on 22 June 2020. Retrieved 5 January 2020.
It had been reported during the season that he had appeared disenchanted as the supplements scandal continued to heavily impact on the club, and in their Round 19 loss to Greater Western Sydney, Carlisle was reported to have yelled "This club is fucked" as he walked to the interchange bench. In October 2015, after much deliberation, Carlisle nominated St Kilda over Carlton as the club he wished to be traded to from Essendon. He was officially traded to St Kilda on 21 October. During his first pre-season with St Kilda, Carlisle and 33 other players who were at Essendon were found guilty of using a banned performance-enhancing substance, thymosin beta-4, as part of Essendon's sports supplements program during the 2012 season. He and his team-mates were initially found not guilty in March 2015 by the AFL Anti-Doping Tribunal, but a guilty verdict was returned in January 2016 after an appeal by the World Anti-Doping Agency. He was suspended for two years which, with backdating, ended in November 2016; as a result, he served approximately fourteen months of his suspension and missed the entire 2016 AFL season. He had also received a two-match internal suspension at St Kilda after footage emerged of him using recreational drugs, but the club later waived it, determining that it was served concurrently with the season-long ban. Carlisle played all 22 games in his first proper season at St Kilda in 2017, following the trade and suspension. The Saints finished mid-table that year with 11 wins and 11 losses.
Sources: en.wikipedia.org
There is a clear relationship between known hydrocarbon discoveries at great depth in the Gulf slope and chemosynthetic communities, hydrocarbon seepage, and authigenic minerals including carbonates at the seafloor. While the hydrocarbon reservoirs are broad areas several kilometers beneath the Gulf, chemosynthetic communities occur in isolated areas with thin veneers of sediment only a few meters thick. The northern Gulf of Mexico slope includes a stratigraphic section more than 10 km (6.2 mi) thick and has been profoundly influenced by salt movement. Mesozoic source rocks from Upper Jurassic to Upper Cretaceous generate oil in most of the Gulf slope fields. Migration conduits supply fresh hydrocarbon materials through a vertical scale of 6–8 km (3.7–5.0 mi) toward the surface. The surface expressions of hydrocarbon migration are called seeps. Geological evidence demonstrates that hydrocarbon and brine seepage persists in spatially discrete areas for thousands of years. The time scale for oil and gas migration from source systems is on the scale of millions of years (Sassen, 1997). Seepage from hydrocarbon sources through faults towards the surface tends to be diffused through the overlying sediment, carbonate outcroppings, and hydrate deposits, so the corresponding hydrocarbon seep communities tend to be larger (a few hundred meters wide) than chemosynthetic communities found around the hydrothermal vents of the Eastern Pacific (MacDonald, 1992). There are large differences in the concentrations of hydrocarbons at seep sites.
Resting metabolic rate generally composes human 60 to 75 percent of TDEE. Because adipose tissue does not use much energy to maintain, fat free mass is a better predictor of metabolic rate. A taller person will typically have less fat mass than a shorter person at the same weight and therefore burn more energy. Men also carry more skeletal muscle tissue on average than women, and other sex differences in organ size account for sex differences in metabolic rate. Obese individuals burn more energy than lean individuals due to increase in the amount of calories needed to maintain adipose tissue and other organs that grow in size in response to obesity. At rest, the largest fractions of energy are burned by the skeletal muscles, brain, and liver; around 20 percent each. Increasing skeletal muscle tissue can increase metabolic rate.
=== Appearance === Semen normally has a whitish-gray colour. It tends to get a yellowish tint as a man ages. Semen colour is also influenced by the food we eat: foods that are high in sulfur, such as garlic, may result in a man producing yellow semen. Presence of blood in semen (hematospermia) leads to a brownish or red coloured ejaculate. Hematospermia is a rare condition. Brown semen is a result of infection, inflammation, trauma or tumor in the urological components such as the urethra, epididymis and seminal vesicles Semen that has a deep yellow colour or is greenish in appearance may be due to medication.Other causes of unusual semen colour include sexually transmitted infections such as gonorrhea and chlamydia, genital surgery and injury to the male sex organs.
Sources: en.wikipedia.org
SR9009 is a synthetic research compound that binds and modulates the nuclear receptors REV-ERBα and REV-ERBβ. It is used in laboratory studies of circadian biology and metabolism, not as an approved medicine. It is also known by the informal name Stenabolic.
No. SR9009 has not been approved as a therapeutic drug in the United States, European Union, or other major markets. Human safety and efficacy data are very limited. Its presence in consumer products does not imply regulatory approval.
The World Anti-Doping Agency lists SR9009 as a prohibited substance because it can alter gene expression and metabolic pathways relevant to performance. The ban applies at all times, not only during competition. Detection relies on laboratory methods such as mass spectrometry.
Laboratories commonly use liquid chromatography coupled with mass spectrometry to detect SR9009. The method can identify the compound and estimate concentration in a sample. Detection limits depend on the matrix and instrument.